BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Efficiency First California - ECPv6.8.2.1//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:Efficiency First California
X-ORIGINAL-URL:https://efficiencyfirstca.org
X-WR-CALDESC:Events for Efficiency First California
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/Los_Angeles
BEGIN:DAYLIGHT
TZOFFSETFROM:-0800
TZOFFSETTO:-0700
TZNAME:PDT
DTSTART:20250309T100000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0700
TZOFFSETTO:-0800
TZNAME:PST
DTSTART:20251102T090000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/Los_Angeles:20251008T090000
DTEND;TZID=America/Los_Angeles:20251008T120000
DTSTAMP:20260406T065248
CREATED:20250626T235120Z
LAST-MODIFIED:20250626T235120Z
UID:67861-1759914000-1759924800@efficiencyfirstca.org
SUMMARY:Advanced Concepts in Designing and Retrofitting Energy Efficient Data Centers
DESCRIPTION:Course description\n\n\n\n\n\nThe class will focus on how to select\, design\, control\, and commission the mechanical systems with the lowest total cost of ownership (TCO) for a given data center. TCO accounts for first cost (including electrical\, architectural and structural impacts)\, reliability\, complexity/simplicity\, energy efficiency\, maintenance costs\, future growth\, and flexibility. The class will make liberal use of real data center case studies for both new construction and retrofits. Mechanical systems evaluated will include packaged/custom direct expansion (DX) with air economizers\, direct/indirect evaporative cooling\, pumped refrigerant economizers\, various chilled water systems including in-row cooling and waterside economizers\, air-cooled chillers with integrated dry-coolers\, liquid cooled racks\, and liquid cooled servers. One area of focus will be controls design and commissioning. This section will cover both Direct Digital Control (DDC) and Programable Logic Controller (PLC) systems\, various controls redundancy options\, failsafe device configuration\, optimizing/simplifying sequences of operation\, and controls commissioning. The class will also review the ASHRAE TC9.9 Thermal Guidelines and other standards of care for control of temperature\, humidity\, gaseous contaminants\, and particulates. Lastly\, the class will cover the growing use of data center heat recovery for building electrification. This is an advanced level course for owners\, operators\, engineers\, contractors\, colocation tenants\, etc. with at least two years of data center experience.
URL:https://efficiencyfirstca.org/event/advanced-concepts-in-designing-and-retrofitting-energy-efficient-data-centers/
LOCATION:Online
CATEGORIES:Pacific Gas & Electric
END:VEVENT
END:VCALENDAR