BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Efficiency First California - ECPv6.8.2.1//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:Efficiency First California
X-ORIGINAL-URL:https://efficiencyfirstca.org
X-WR-CALDESC:Events for Efficiency First California
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/Los_Angeles
BEGIN:DAYLIGHT
TZOFFSETFROM:-0800
TZOFFSETTO:-0700
TZNAME:PDT
DTSTART:20260308T100000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0700
TZOFFSETTO:-0800
TZNAME:PST
DTSTART:20261101T090000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/Los_Angeles:20260521T093000
DTEND;TZID=America/Los_Angeles:20260521T130000
DTSTAMP:20260428T152056
CREATED:20260428T190912Z
LAST-MODIFIED:20260428T190912Z
UID:69382-1779355800-1779368400@efficiencyfirstca.org
SUMMARY:ASHRAE Guideline 36 Best in Class HVAC Control Sequences
DESCRIPTION:ASHRAE Guideline 36\, High Performance Sequences of Operation for HVAC Systems\, was created to develop and maintain best in class standardized HVAC control sequences. This guideline allows engineers to reduce engineering time by adapting standard sequences already proven to perform. It also minimizes programming and commissioning time for contractors through the use of preprogrammed and pre tested control logic that is being developed by building automation system manufacturers. ASHRAE Guideline 36 reduces energy consumption\, improves implementation quality and reliability\, and helps ensure compliance with current codes and standards. \nThis course introduces the current version of ASHRAE Guideline 36 and presents an overview of key sequences of operations. The discussion will include the research underlying the current sequences as well as ongoing and planned future research intended to develop additional advanced sequences for other HVAC system types. Attendees will learn about how to use ASHRAE Guideline 36 sequences and how they improve energy efficiency\, thermal comfort\, and indoor air quality. \n\nAgenda\n\n\nIntroduction and safety message\nTraining overview\nIntroduction to Guideline 36\nGeneral control logic\nZone level control sequences\nMultiple zone air handling units\nImplementing Guideline 36\nRelated research\n\n\n\n\nObjectives\n\nThe objective of this course is that at the conclusion\, participants will be able to: \n\nAnalyze the key innovative sequences in ASHRAE Guideline 36\, High Performance Sequences of Operation for HVAC Systems\nAchieve energy savings through HVAC control upgrades and the implementation of ASHRAE Guideline 36 control sequences\nExplain the advantages of using standardized advanced sequences to designers\, contractors\, and owners\nExplore how to implement Guideline 36 sequences in new and existing buildings for engineers and contractors\n\n\n\n\nAudience Level\nAdvanced
URL:https://efficiencyfirstca.org/event/ashrae-guideline-36-best-in-class-hvac-control-sequences/
CATEGORIES:Pacific Gas & Electric
END:VEVENT
END:VCALENDAR