BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//Efficiency First California - ECPv6.8.2.1//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://efficiencyfirstca.org
X-WR-CALDESC:Events for Efficiency First California
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/Los_Angeles
BEGIN:DAYLIGHT
TZOFFSETFROM:-0800
TZOFFSETTO:-0700
TZNAME:PDT
DTSTART:20260308T100000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0700
TZOFFSETTO:-0800
TZNAME:PST
DTSTART:20261101T090000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/Los_Angeles:20260715T140000
DTEND;TZID=America/Los_Angeles:20260715T160000
DTSTAMP:20260805T090638
CREATED:20260623T233105Z
LAST-MODIFIED:20260623T233105Z
UID:69636-1784124000-1784131200@efficiencyfirstca.org
SUMMARY:Recovery Ventilator: Installation\, Energy Savings\, and Compliance
DESCRIPTION:Event Description \nImproved health and cognitive performance. Easier Title 24 compliance. Utility bill savings. These are the reasons to consider incorporating Heat Recovery Ventilators & Energy Recovery Ventilators (collectively Recovery Ventilators or RVs) into your next high-performance home project. \nThe instructors are a high-performance home contractor and energy consultant\, who together have specified and installed hundreds of RVs. They will draw on these experiences and data gathered from these units to better understand these mechanical ventilation systems and their benefits. They will cover the details of ducting to the outside for inlet and exhaust air and distributing the supply and exhaust throughout homes. Balancing airflow rates and maintenance requirements will also be covered. \nWe will also go over new 2025 energy code requirements for balanced ventilation and heat recovery in multifamily dwelling units\, how to add a RV to a Title 24 compliance energy model and the change in energy use and compliance metrics that results. We’ll present various configurations of RVs\, including through-the-wall paired units\, packaged HRVs and packaged ERVs\, and various ducting options. \nLearning Objectives \n\nUnderstand the basics of how Recovery Ventilators (RVs) work to improve indoor air quality in homes and reduce heating and cooling energy use\nLearn the 2025 energy code requirements for mechanical ventilation in single family and multifamily buildings and how RVs impact Title 24 compliance metrics\nModel a case study home and multifamily building using RVs and examine the energy use and compliance scores in various configurations\nHear best practices for specifying and installing RVs\n\nLearning Units  \n\n2.0 AIA LUs pending for this course\n0.2 ICC CEUs pending for this course\n2.0 CEA CEUs pending for this course\n\nInstructors  \nNick Brown\, Build Smart Group \nScott Kelly\, SK Fresh Air \nCourse Location  \nZoom link provided upon registration
URL:https://efficiencyfirstca.org/event/recovery-ventilator-installation-energy-savings-and-compliance/
CATEGORIES:3C-REN
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/Los_Angeles:20260722T093000
DTEND;TZID=America/Los_Angeles:20260722T110000
DTSTAMP:20260805T090638
CREATED:20260623T233230Z
LAST-MODIFIED:20260623T233230Z
UID:69638-1784712600-1784718000@efficiencyfirstca.org
SUMMARY:Next Generation Passive Solar & Passive House
DESCRIPTION:Event Description \nWe all learned the principles of passive solar design in school – south facing orientation\, strategic windows\, thermal mass\, etc.\, but the old rules don’t apply in the same way. In the meantime\, Passive House building principles are folding into every-day construction. Modern buildings should still incorporate a range of passive strategies\, but they need a new spin on the implementation to account for improved insulation\, prevalence of high-performance glazing\, and efficient HVAC systems and lighting. \nLearning Units \n1 AIA LUs pending for this course \nInstructors \nJennifer Rennick\, In Balance Green Consulting \nAndy Pease\, In Balance Green Consulting \nCourse Location \nZoom link provided upon registration.
URL:https://efficiencyfirstca.org/event/next-generation-passive-solar-passive-house/
CATEGORIES:3C-REN
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/Los_Angeles:20260730T093000
DTEND;TZID=America/Los_Angeles:20260730T110000
DTSTAMP:20260805T090638
CREATED:20260623T233407Z
LAST-MODIFIED:20260623T233407Z
UID:69640-1785403800-1785409200@efficiencyfirstca.org
SUMMARY:Using the ECC (HERS) Registry for Energy Code Compliance
DESCRIPTION:Event Description \nThis class teaches building department personnel how to use the ECC (formerly HERS) Registry to track the status of all of the ECC tests and inspections\, as well as all of the other compliance documents: CF1R\, CF2Rs\, and CF3Rs. The Project Status Report generated by the registry is probably the single most valuable tool for building departments to ensure compliance with the energy code. \nLearning Objectives \n\nWhat the ECC program is in the energy code\nHow ECC verification fits into the overall compliance process\nWhen a project is required to be registered with an ECC provider and when it is not\nHow to find a project in an ECC registry\nHow to use the ECC registry to track compliance documentation for a project\nHow to use the ECC registry to save time on field inspections\n\nLearning Units  \n\n1.5 AIA LUs pending for this course\n0.15 ICC CEUs pending for this course\n1.5 CEA CEUs pending for this course\n\nInstructor \nRuss King\, Coded Energy \nCourse Location  \nZoom link provided upon registration
URL:https://efficiencyfirstca.org/event/using-the-ecc-hers-registry-for-energy-code-compliance/
CATEGORIES:3C-REN
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/Los_Angeles:20260813T070000
DTEND;TZID=America/Los_Angeles:20260813T083000
DTSTAMP:20260805T090638
CREATED:20260723T193214Z
LAST-MODIFIED:20260723T193214Z
UID:69681-1786604400-1786609800@efficiencyfirstca.org
SUMMARY:Heat Pump Water Heater Installation Training at Cedar Valley Plumbing Oxnard
DESCRIPTION:Event Description \nHeat pump water heaters (HPWH) are becoming the standard in California. This free training will prepare your plumbers to install them correctly to avoid callbacks and achieve their full potential in terms of efficiency\, capacity\, longevity\, and customer satisfaction. We’ll cover how they work\, the range of models available on the market\, the critical detail of air flow\, and research on closet installs and condensation risk. You’ll come out prepared to add heat pump water heaters to your business and avoid some common installation hurdles. \nNick Brown is an expert on energy efficiency and Title 24 and has two heat pump water heaters operating at his house under continuous monitoring. \nLearning Objectives \n\nAcquire practical skills through a hands-on demonstration on installing a HPWH in a closet\nExplore the do’s and don’ts of installation based on real-life examples\nUnderstand the importance of air flow for HPWHs\nDistinguish how HPWHs are different from typical water heaters\n\nInstructors \nNick Brown\, Build Smart
URL:https://efficiencyfirstca.org/event/heat-pump-water-heater-installation-training-at-cedar-valley-plumbing-oxnard/
LOCATION:Cedar Valley Plumbing – Oxnard\, 1710 Westar Drive\, Oxnard\, CA\, 93033\, United States
CATEGORIES:3C-REN
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/Los_Angeles:20260819T100000
DTEND;TZID=America/Los_Angeles:20260819T110000
DTSTAMP:20260805T090638
CREATED:20260723T193439Z
LAST-MODIFIED:20260723T193439Z
UID:69685-1787133600-1787137200@efficiencyfirstca.org
SUMMARY:Ask the Experts: Energy Compliance & Modeling
DESCRIPTION:Event Description \nJoin us for an office-hours style open discussion focused on energy code compliance and performance modeling. This interactive session gives participants direct access to experts who can help clarify Energy Code requirements\, compliance forms\, modeling approaches\, and energy modeling software. Bring your questions and real-world project challenges! The conversation will be guided by the needs and questions of attendees. \nThe session will be led by Grant Murphy of In Balance Green Consulting\, one of 3C-REN’s Energy Code Coaches. Grant is a Certified Energy Analyst with extensive experience in energy code compliance and performance modeling\, and he brings a practical\, real-world perspective to helping project teams navigate energy code requirements with confidence. \nInstructors  \nGrant Murphy\, In Balance Green Consulting \nCourse Location  \nZoom link provided upon registration
URL:https://efficiencyfirstca.org/event/ask-the-experts-energy-compliance-modeling/
CATEGORIES:3C-REN
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/Los_Angeles:20260820T140000
DTEND;TZID=America/Los_Angeles:20260820T160000
DTSTAMP:20260805T090638
CREATED:20260723T193633Z
LAST-MODIFIED:20260723T193633Z
UID:69687-1787234400-1787241600@efficiencyfirstca.org
SUMMARY:Introduction to Residential HVAC Design
DESCRIPTION:Event Description \nThis class will cover the basics of residential HVAC design following the industry standard and code-referenced ACCA Manuals J\, S and D. It will discuss the four steps of the design process: \n\nCollecting information about the house.\nPerforming load calculations (Manual J)\nSelecting equipment appropriate to the load calculations (Manual S)\nDesign a duct system for efficiency and comfort (Manual D)\n\nIt will also discuss some of the new technologies and software that has reduced the time it takes to do a design by up to 75%. \nLearning Objectives \n\nUnderstand the basic terminology and concepts\nUnderstand the ACCA Manuals\nUnderstand the basic steps in the design process\nLearn about new technologies and software that make the process much faster\n\nLearning Units  \n\n2.0 AIA LUs pending for this course\n\nInstructors  \nRuss King\, Coded Energy \nCourse Location  \nZoom link provided upon registration
URL:https://efficiencyfirstca.org/event/introduction-to-residential-hvac-design/
CATEGORIES:3C-REN
END:VEVENT
END:VCALENDAR